Other university all, Electrical Engineering , Switch gear and protection Syllabus

Switch gear and protection Lecture notes | Videos | Free pdf Download | Previous years solved question papers | MCQs | Question Banks| Syllabus
Get access to 100s of MCQs, Question banks, notes and videos as per your syllabus.
Try Now for free

Switch gear and Protection

CREDITS - 03

Unit - 1

Fundamentals of protective relaying 
Need for protective system, nature and causes of fault, types of faults, effects of faults, evolution of protective relaying, classification of relays, zones of protection, primary and backup protection, essential qualities of protective relaying. Trip circuit of circuit breaker, zone of protection. Various basic operating principles of protection- over current, (current graded and time graded ), directional over current, differential, distance, induction type relay, torque equation in induction type relay, current and time setting in induction relay, Numericals on TSM , PSM and operating time of relay


Unit - 2

Fundamentals of arc interruption 
Ionization of gases, deionization, Electric arc formation , Current interruption in AC circuit breaker, high and low resistance principles, arc interruption theories, arc voltage, recovery voltage, derivation and definition of restriking voltage and RRRV, current chopping, interruption of capacitive current, resistance switching, Numerical on RRRV, current chopping and resistance switching.

Unit - 3

Circuit Breaker 
Different ratings of circuit breaker (like rated voltage, rated current, rated frequency, rated breaking capacity – symmetrical and unsymmetrical breaking, making capacity, rated interrupting duties, rated operating sequence, short time rating). Classification of high voltage circuit breaker. Working and constructional features of ACB, SF6 VCB- advantages, disadvantages and applications. Auto reclosing.

 

Unit - 4

A) Static and Digital Relaying
Overview of Static relay, block diagram, operating principal, merits and demerits of static relay. Numerical Relays :-Introduction and block diagram of numerical relay, Sampling theorem, Anti –Aliasing Filter, Block diagram of PMU
B) 3 Phase Induction Motor Protection
Abnormal conditions and causes of failures in 3 phase Induction motor, single phasing protection, Overload protection, Short circuit protection.

Unit - 5

A) Transformer Protection
Types of faults in transformer, Percentage differential protection in transformers, Restricted E/F protection, incipient faults, Buchholz relay, protection against over fluxing, protection against inrush current,
B) Alternator Protection
Various faults in Alternator, abnormal operating conditions- stator faults, longitudinal percentage differential scheme and transverse percentage differential scheme. Rotor faults-abnormal operating conditions, inter turn fault, unbalance loading, over speeding, loss of excitation, protection against loss of excitation using offset Mho relay, loss of prime mover.

Unit - 6 

Transmission line protection 
Over current protection for feeder using directional and non directional over current relays, Introduction to distance protection, impedance relay, reactance relay, mho relay and Quadrilateral Relays, Introduction to PLCC, block diagram, advantages, disadvantages, three stepped distance protection, Effect of arc resistance, and power swing on performance of distance relay. Realization of distance relays(impedance, reactance, and mho relay) using numerical relaying algorithm(flowchart, block diagram), Introduction to Wide Area Measurement (WAM) system.

Share  
Link Copied
More than 1 Million students use Goseeko! Join them to feel the power of smart learning.
Spot anything incorrect? Contact us