S2
UNIT-3TRIGONOMETRIC LEVELLINGQ1.What are the types of trigonometric levelling?A1) It is of 2 types:- 1.plain trigonometric levelling: the principle of plain surveying are employed .it is assumed that the distance measured is small compared to the radius of earth and thus the effect of earth curvature and refraction can be ignored 2.Geodetic trigonometric levelling: In this method, the distance between the points is comparable to that of earth radius and thus the simple principles of plain surveying cannot be applied.it requires the correction due to earth curvature and refraction.Q2.What is trigonometric levelling?A2) In this method, the difference in elevation between two points can be found by measuring the inclined or horizontal distances and the zenith or altitude angles is called trigonometricQ3.Determination of elevation of object when the base is accessible and inaccessible by single plane method?A3) Case (1) if horizontal distance up to the point can be mean.
Fig-1 if horizontal distance up to the point can be mean Given values:-Distance 'D' Angle= Staff reading Vertical height V = D tan R.L. of B = RL of B.M. + C= combined correction due to Earth curvature/ refraction = (+) 0.0673 [positive for RL] Case (2) If distance D cannot be measured Given (known) values:-Distance 'B' = AB Staff readings The difference between staff readings 3 Angle measured3. From 4. From 4 RL of BM
Fig-2 If distance D cannot be measured
V+S=(B+D)tanθ1 (1) RL of Q4. Determine the elevation of the object by single plane method ?A4) To find out the Reduced Level (R.L.) of inaccessible elevated point by Trigonometrical Levelling. Instruments required: Theodolite, Levelling staff, Ranging rod, Tape. Given data:Elevation of B.M. = 100.000 m General:(a)Trigonometry is the process of determining the differences of elevation of the stations from observed vertical angles and known horizontal distance either measured directly or computed trigonometrically.(b) Instruments stations and the elevated object are in the same plane. Procedure:1. Set up the theodolite at A, level it carefully and observe the angle of elevation a1.2. Set the vertical vernier to zero, and take a reading on a staff held vertically on a BM. Let it be S13. Transit the telescope, so that the line of sight is reversed.4. Mark a point B in the line of sight at a convenient distanced, Measure it accurately,5. Shift the theodolite to point B, Centre it and level it. Observe the angle of elevation a2.6. Set the vertical vernier to zero and take again a B.M., reading as S2.Q5. Determine the elevation of the object by double plane method ?A5) Aim:To find out the R.L. of the inaccessible elevated point by Trigonometrical Levelling with the instrument at double vertical plane. Instruments Required:Theodolite, Levelling staff, Ranging rod, Tape. Given Data:R.L. of the B.M. = 100. 000m. General: Instrument stations and the elevated objects are in different planes. Procedure: 1. Let the given point is “B”2. Set up the theodolite station A, centre it carefully and fix the ranging rod at C of known distance “d”3. Measure horizontal angles BAC, Let it be q1, in angles BAC should be individually equal to 30° to 75°.4. Sight ‘B’ the top of the object and observe the angle of elevation a1 ensuring that altitude bubble is centre of its run.5. Setting the vertical vernier to zero take a reading on a staff held vertically on a benchmark. Let the reading be S1.6. Shift the theodolite the station C at a known distance ‘d’ and centre it over the mark and observe that the horizontal angle BCA. Let it be q2.7. Sight ‘B’ the top of the object and observe the angle of elevation a2, ensuring that the altitude bubble is central of its run.8. Setting up the vertical vernier to zero takes a reading on a staff on the same benchmark. Let it be S2.9. Measure the horizontal distance ‘d’ between stations A and C.Q6.What is total station?A6) A total station is an electronic/optical instrument used in modern surveying and building construction that uses electronic transit theodolite in conjunction with electronic distance meter (EDM). It is also integrated with microprocessor, electronic data collector and storage system.The instrument is used to measure the sloping distance of the object to the instrument, horizontal angles and vertical angles. This Microprocessor unit enables for computation of data collected to further calculate the horizontal distance, coordinates of a point and reduced level of the point.Q7.What are the parts and accessories of total station?A7) There are mainly four main components which areEDM (Electronic Distance Measurement), electronic theodolite, microprocessor and electronic display Accessories of Total StationAccessories of the total station are as follows:-Total Station Battery & Charger, Total Station Prism, Total Station Tripod & Bipod, Total Station Prism Pole and Stand For Total Station. Q8.What are the error in total station?A8) Total Station Errors:- 1 CALIBRATION OF TOTAL STATIONS Maintaining the high level of accuracy offered by modern total stations, there is much more emphasis on monitoring instrumental errors, and some construction sites require all instruments to be checked regularly using procedures outlined in the quality manuals. Some instrumental errors can be eliminated by observing on two faces of the total station and averaging, but because one face measurements are the preferred method on-site, it is important to determine the amount of instrumental errors and correct for them.For total stations, instrumental errors are measured and corrected by electronic calibration procedures that are carried out at any time and are applied to the instrument on-site. Since calibration parameters can change due to mechanical shock, temperature changes and rough handling of the high-precision instrument, an electronic calibration should be carried out on a total station as follows:Before using the instrument for the first time After long storage periods After rough or long transportation After long periods of work Following big changes in temperature Regularly for precision surveys Before every calibration, it is essential to allow the total station enough to reach the ambient temperature. 2 HORIZONTAL COLLIMATION (OR LINE OF SIGHT ERROR) This axial error happens when the line of sight is not perpendicular to the tilting axis. It affects all horizontal circle readings and increases parallel to steep sightings, but this is eliminated by observing on two faces. For single face measurements, an on-board calibration function is used to determine c, the deviation between the actual line of sight and a line perpendicular to the tilting axis. A correction will be applied automatically for this to all horizontal circle readings.
Fig-3 LINE OF SIGHT ERROR3 TILTING AXIS ERROR axial errors occur when the tilting axis of the total station is not perpendicular to its vertical axis, this does not affect sightings taken when the telescope is horizontal but produces errors into horizontal circle readings when the telescope is tilted, especially for steep sightings. But with horizontal collimation error, this error is erased by two face measurements, or the tilting axis error (a) is measured in a calibration procedure and a correction applied for this to all horizontal circle readings. 4 COMPENSATOR INDEX ERRORErrors that were caused by not levelling a theodolite or total station carefully cannot be eliminated by taking face left and face right readings. If the total station is fitted with a compensator it will measure residual tilts of the instrument and will apply corrections to the horizontal and vertical angles for these.All compensators will have a longitudinal error l and traverse error t known as zero-point errors which are averaged using face left and face right readings but for a single face, readings must be determined by the calibration function of the total station.
Fig-4 COMPENSATOR INDEX ERROR A vertical collimation error exists on a total station if the 0o to 180o line in the vertical circle does not coincide with its vertical axis and this zero point error is present in all vertical circle readings and like the horizontal collimation error, it is eliminated by taking FL and FR readings or by determining i Any difference between the measured horizontal and vertical angles is then identified as an instrumental error and applied to all readings. The total station is thus calibrated and the procedure is the same for all of the error type.
Fig-4 COMPENSATOR INDEX ERROR (correction)Q9.What are the uses of total station?A9) Total Station uses in the following areas:-Road Survey Rail Survey Canal Survey My Survey Engineering Survey Large Scale Survey Q10.What are the field procedure of total station?A10) Step-1: Setting up the of the instrument along with the tripodStep-2: Levelling of the instrument approximately with the help of “bull’s eye bubble” and then verifying the levelling electronicallyStep-3: Adjustment of reticle focus and image.Step-4: Recording all the measurementsStep-5: Data ProcessingStep 1: Tripod Setup tripod legs should be equally space tripod head should be approximately levelnHead should be directly over survey pointStep 2: Mount Instrument on TripodnPlace Instrument on Tripod secure with centring screw while bracing the instrument with the other hand insert battery in the instrument before levellingStep 3: Focus on Survey PointnFocus the optical plummet on the survey pointStep 4: Leveling the InstrumentnAdjust the levelling foot screws to centre the survey point in the optical plummet reticle centre the bubble in the circular level by adjusting the tripod legsStep 4: Leveling ... loosen the horizontal clamp and turn instrument until plate level is parallel to 2 of the levelling foot screws centre the bubble using the levelling screws- the bubble moves toward the screw that is turned clockwise rotate the instrument 90 degrees and level using the 3rd levelling screwStep 4: Leveling ... nObserve the survey point in the optical plummet and centre the point by loosening the centring screw and sliding the entire instrument after re-tightening the centring screw check to make sure the plate level bubble is level in several directionsStep 5: Turn on the instrument by pressing and holding the “on” button The opening screen will be the “MEAS” screen. Select the Tilt function and then adjust the foot level screws to exactly centre the electronic “bubble
V+S=(B+D)tanθ1 (1) RL of Q4. Determine the elevation of the object by single plane method ?A4) To find out the Reduced Level (R.L.) of inaccessible elevated point by Trigonometrical Levelling. Instruments required: Theodolite, Levelling staff, Ranging rod, Tape. Given data:Elevation of B.M. = 100.000 m General:(a)Trigonometry is the process of determining the differences of elevation of the stations from observed vertical angles and known horizontal distance either measured directly or computed trigonometrically.(b) Instruments stations and the elevated object are in the same plane. Procedure:1. Set up the theodolite at A, level it carefully and observe the angle of elevation a1.2. Set the vertical vernier to zero, and take a reading on a staff held vertically on a BM. Let it be S13. Transit the telescope, so that the line of sight is reversed.4. Mark a point B in the line of sight at a convenient distanced, Measure it accurately,5. Shift the theodolite to point B, Centre it and level it. Observe the angle of elevation a2.6. Set the vertical vernier to zero and take again a B.M., reading as S2.Q5. Determine the elevation of the object by double plane method ?A5) Aim:To find out the R.L. of the inaccessible elevated point by Trigonometrical Levelling with the instrument at double vertical plane. Instruments Required:Theodolite, Levelling staff, Ranging rod, Tape. Given Data:R.L. of the B.M. = 100. 000m. General: Instrument stations and the elevated objects are in different planes. Procedure: 1. Let the given point is “B”2. Set up the theodolite station A, centre it carefully and fix the ranging rod at C of known distance “d”3. Measure horizontal angles BAC, Let it be q1, in angles BAC should be individually equal to 30° to 75°.4. Sight ‘B’ the top of the object and observe the angle of elevation a1 ensuring that altitude bubble is centre of its run.5. Setting the vertical vernier to zero take a reading on a staff held vertically on a benchmark. Let the reading be S1.6. Shift the theodolite the station C at a known distance ‘d’ and centre it over the mark and observe that the horizontal angle BCA. Let it be q2.7. Sight ‘B’ the top of the object and observe the angle of elevation a2, ensuring that the altitude bubble is central of its run.8. Setting up the vertical vernier to zero takes a reading on a staff on the same benchmark. Let it be S2.9. Measure the horizontal distance ‘d’ between stations A and C.Q6.What is total station?A6) A total station is an electronic/optical instrument used in modern surveying and building construction that uses electronic transit theodolite in conjunction with electronic distance meter (EDM). It is also integrated with microprocessor, electronic data collector and storage system.The instrument is used to measure the sloping distance of the object to the instrument, horizontal angles and vertical angles. This Microprocessor unit enables for computation of data collected to further calculate the horizontal distance, coordinates of a point and reduced level of the point.Q7.What are the parts and accessories of total station?A7) There are mainly four main components which are
0 matching results found