Unit 3
Radiographic Methods
Q1) Explain electromagnetic waves and radioactivity.
Answer: Electromagnetic Waves:
Electromagnetic waves are coupled electric and magnetic oscillations that move with the speed of light and exhibit typical wave behaviour.
The following properties are associated with electromagnetic waves traveling through free space:
Radioactivity:
The disintegration of nuclei of high atomic number into a lower atomic number is known as radioactivity. It is found that in elements of an atomic number higher than 82, repulsive forces are very high and such elements are no longer stable.
These elements start disintegrating to form stable elements of lower atomic numbers. During the process of disintegration, alpha particles, beta particles, and gamma rays are emitted.
Radioactive disintegration occurring per unit time is proportional to the total number of radioactive atoms present
.=λN, where λ=Constant of proportionality
N= Number of radioactive atoms present
The negative sign indicates a decrease in number with time.
Q2) Explain various types of decays in radioactivity.
Answer: There are five types of decay, all are mentioned here:
The emission of alpha particles reduces the size of the nucleus. The main reason for the instability is the larger size of the nucleus.
2. Beta Decay:
The emission of an electron by a neutron in the nucleus changes the neutron to a proton. The main reason behind the instability is the nucleus has too many neutrons relative to the numbers of protons.
3. Positron Emission:
Emission of positron by a proton in the nucleus changes the proton to a neutron. The reason behind instability is the nucleus has too many protons relative to some neutrons.
4. Electron Capture:
The capture of an electron by a proton in the nucleus changes the proton to a neutron. The reason behind the instability is the nucleus has too many protons relative to some neutrons.
5. Gamma Decay:
The emission of gamma rays reduces the energy of the nucleus. The reason behind instability is nucleus has excess energy.
Q3) Define the photoelectric effect and Compton’s effect.
Answer: Photoelectric effect:
When a photon of X-ray of relatively low energy passes through a material and gets collided with an atom of the material, it kicks off an electron from the material surface and these electrons can be detected as a change in the electric charge of the metal or as an electric current.
This ejection of an electron from the shell of the atom ionizes the atom and this ionized atom returns to the equilibrium or neutral state with the emission of X-ray characteristics of the atom.
This phenomenon is called a photoelectric effect and occurs in the object, in the film, and in any filters used.
Compton’s Effect (Incoherent scattering):
When photons of X-ray with higher energies (100 KeV to 10MeV) get interacted with an electron, causes a part of the energy of photons to be transferred to the electrons, and the electron gets ejected from its orbital position.
At the same time, photons continue to travel through the material along the deflected path from the initial angle of incidence and scattered X-ray photons emerges as radiation of reduced energy, Scattered in all direction.
Since scattered X-ray photon has less energy, it will have a longer wavelength and less intensity of penetration than the incident photon. The change in wavelength of the scattered X-ray photon is given by,
Where λ’-λ= (h/Cme)(1-cosθ)
λ’=Wavelength of incident X-ray photon
λ=Wavelength of scattered X-ray photon
h=Planck’s constant, C= speed of light,
me=mass of the electron, θ=angle at which scattering takes places
Q4) What is Beam Geometry?
Answer: X-ray and gamma rays both obey the common law of light. The formation of the shadow of any object is also a property of light. Naturally, the shadow cast by the object will show some enlargement and this enlargement of the shadow is calculated as degree or enlargement which is mathematically expressed as,
(S0/Ss) = (D0/Ds) where, S0 = Size of the object, Ss=Size of the shadow, D0=Distance from the source of radiation, and Ds= distance from the source of radiation to the recording surface.
Similarly, the degree of sharpness of any shadow depends on the size of the source of light and the position of the object.
Radiations from X-ray tubes and radioactive source always produce radiographic images with a certain amount of blurring, which is called unsharpness (Ug)
(Ug)=(S.DD)/(DF-DD) where, (Ug)= geometric unsharpness, S=Size of source and DD=Distance between defect and film
The maximum value of Ug can be calculated through expression,
(Ug)max=(S.t)/(DF-t), where, t=thickness of the object
From the above equation, it is very much clear that geometric unsharpness can be reduced to any limit between source and film.
Q5) Explain the Scattering factor.
Answer: When an X-ray or gamma-ray passes through any object, it gets attenuated due to absorption and scattering of radiation.
The attenuation of radiation depends upon the uniformity of the object. If the object is uniform then the attenuation will be uniform and the radiation image will be evenly exposed. When the radiation beam is focused on any object, some part of the radiation is transmitted through the object and forms the image. Some get scattered contributing to the non-forming of image.
Thus the total radiation is the sum of transmitted radiation and scattered radiation.
Total radiation=Rt+Rs
The ratio of transmitted radiation and scattered radiation is called the scattered radiation factor or scattering factor.
Scattering factor=( Rt/Rs)
Q6) What is the principle and methodology of X-ray radiography?
Answer: The principle and methodology are mentioned below:
Principle
X-rays are produced when a high-speed moving electron get collided with the nucleus of an atom, x-rays are produced in an X-ray tube which consists of a glass or ceramic envelope containing an anode, a positively charged electrode, evacuated to an ultra-high vacuum of 109 hectopascals.
Cathode acts s a producer of electrons, when electrical tension is set up between the cathode and anode, these electrons are attracted by the anode and get accelerated up.
These electrons from the cathode are connected into a beam by a focusing cup and when these electrons get collided with the anode, a part of their energy is transformed into X-radiations called X-rays.
Methodology:
The main components of X-ray radiography are the tube, the high voltage generator, the control console, and the cooling system.
X-rays are generated by directing steam of high-speed electrons at a target material such as tungsten, which has the highest atomic number. When the electrons are slowed or stopped by the interaction with the atomic particles of the target, X-radiation is produced.
In X-ray equipment, there is a glassed enclosed tube known as an X-ray tube, consists of a glass bulb under vacuum, a negatively charged electrode known as the cathode, and a positive electrode known as the anode. The cathode is in form of a filament.
When the suitable current of few amperes is applied to the filament, it emits electrons which are then attracted by the anode. The stream of electrons is concentrated in the form of a beam of high-speed particles.
As the beam high-speed electrons strike the targeted it produces X-rays.
Electrons striking with more energy results in X-rays with higher penetrating power. The area struck by the high-speed electron beam is called the target of the focal spot.
The projection of the focal spot on the surface perpendicular to the axis of a beam is known as optical focus. A pinhole is made in thick material; it is aligned parallel to the tube axis and perpendicular to the beam of X-rays.
Because the defect possesses a lesser density than the parent metal, they transmit the X-rays better than the parent metal. Thus a dark radiographic image of defects obtained.
Q7) Describe the major categories of radiations.
Answer: There are three types of radiations are there mentioned below:
These rays are produced by an X-ray generator and gamma radiation is the product of radioactive atoms. X-rays are an extremely short wavelength, a form of electromagnetic radiation that is capable of penetrating many materials that reflect or absorbs visible light.
X-rays are generated from X-ray tube equipment. They are operating at 400 kV, can inspect steel objects having a thickness up to 60 mm.
2. Gamma-ray:
These rays are emitted during the disintegration of radioactive nuclei. It is also electromagnetic radiation of short wavelength.
It has high penetrating power than X-rays so that it is generally used in industrial applications.
3. Neutron Beam:
Various radioactive isotopes are used as the radiation source. Neutron beams are generally derived from nuclear reactors, radioisotopes, or nuclear accelerators.
For most applications, it is necessary to moderate the energy and collimate the beam before use.
Q8) What is the principle behind gamma-ray radiography? Illustrate the types of equipment provided for Gamma radiography.
Answer: The basic principle and the major equipment used in gamma radiography is mentioned below:
Gamma rays in the range of 102-104 GeV are sometimes termed as very high gamma rays, while those above 1014 eV are termed as ultra high energy gamma rays.
It is different from X-ray radiography. It is a product of radioactive atoms that depends on the ratio of neutrons to protons within its nucleus, an isotope of a particular element may be stable or unstable.
2. Equipment used:
Q9) What are precautions need to be taken against radiation hazards? Mention.
Answer: Under the aspect of precautions against radiation hazards certain rules are necessary:
Q10) Brief the case study of gamma-ray radiography for casting.
Answer: Gas porosity appears as round or elongated smooth dark spots, occurring individually throughout the casting. This is caused by gas formation during solidification by the evaporation of moisture from the mould surface.
Gas holes appear as dark circular images, isolated or in clusters. These are caused by gas entrapment in molten metal. If the molten metal solidifies before all gases escape, the gas is entrapped in the casting resulting in gas holes.
Shrinkage appears as dendrite, filamentary or jagged darkened areas. These are caused due to contraction of metal while the casting solidifies.
Cold shut appears as a dark line of variable length with a definite, smooth outline. Cold shuts are formed when two streams of molten metal flowing from different directions fail to unite. The formation of a cold shut is due to interrupted pouring the metal at too low temperature.
Misruns appears as a prominent, darkened area of varying dimensions with a definite, smooth outline. These are produced by the failure of the molten metal to fill a section of casting.